1 something is overheating driving your fan to max.

Hp dl360p gen8 fan noise.

Skip to 3 30 to hear the fans start ramping down. When a computer fan spins loudly for a long period of time there might be an issue with a fan or the computer might be overheating. I m viewing the temperatures and fan speeds through ilo there are no indications of any errors all the leds are green no fans have failed or acted weirdly in any way and there are no pcie cards installed. Hp notebook pcs fan is noisy and spins constantly windows this document is for hp notebook pcs.

Fans tend to be loud for two primary reasons. Additionally noise is a factor here. If this doesn t fix the problem then figure out what the fan is suppose to be cooling look to replacing that component. Common best to just order a replacement fan replace it.

Follow the following guidelines for fan configuration. Dl360p gen8 fans noisy 94 speed after firmware update ok i have fixed the issue by downgrading the p420i driver to v7 02now the leds are back on and the fans are back to 19 and the server isn t complaining about non hp disks. We have dl360p g8 server which has non hp memeory and non hp hdd drive with p420i controller this server located in datacenter and somehow found its running noisy and on ilo its showing fan running on 94 speed all i have download all firmware and upgraded my bios setting is optiomal cooling for fan. So i m pretty sure the closet is the main reason for high temperatures.

Hot plug fan removal instructions. Rare 2 you have a fan bearing going out. Adjust the power settings clean the fan vents check for suspicious processes and then update the bios to help. To provide sufficient airflow to the system if a fan rotor fails the server supports redundant fans.

In a single processor nonredundant configuration fans 5 6 7 and 8 cool the server to enable the redundant fan mode install a new fan in. To view a video demonstrating the procedure for removing replacing the hot plug fan click here to view the hpe services media library and then click on servers proliant dl servers hpe proliant dl360e gen8 server and then click on remove replace on the new window select hot plug fan from the menu on the upper left hand side of the screen.

Silencing A Hp Dl380 Gen8 Homelab

Silencing A Hp Dl380 Gen8 Homelab

Dl360p G8 Fan Speed Frustrations Homelab

Dl360p G8 Fan Speed Frustrations Homelab

Starting Up Booting A Hp Proliant Server Dl380p Gen8 Youtube

Starting Up Booting A Hp Proliant Server Dl380p Gen8 Youtube

Hp Proliant Dl360p Gen8 Server Seriously Sysadmin

Hp Proliant Dl360p Gen8 Server Seriously Sysadmin

Source : pinterest.com